DISCONNECT THE SAW FROM
THE MAINS SUPPLY!
Checking the Table is Square
1) Loosen the clamping handle beneath the table, lower the
table until it rests against its stop. This is a bolt with a lock nut
screwed into the underside of the table, see fig 50. The head
of the bolt acts as a stop when it strikes the machine frame.
Tighten the clamping handles.
2) Loosen the blade guide clamp and raise the upper blade
guide assembly as high as possible, see fig 51. Place a
90˚square on the table and move it up against the blade
(behind the teeth), see fig 52.
Fig 50
Fig 51-52
Table stop bolt
21
SETTING UP THE SAW
3) Check that the blade is perpendicular to the table. If it is not,
try resetting the table by loosening the lift & shift handles and
adjusting the table stop nut until perpendicularity is achieved,
see fig 53.
4) Move the square up against the back of the blade and check
it's square against the table, see fig 54. If adjustment is required,
adjust the grub screws beneath the mounting plate, make
small adjustments, lower the table and postion the square as
before. Continue until the blade is square to the table. Tighten
the tables bolts to secure in place, see fig 55-56-57. Note: check
the blade is still square against the table as shown in fig 54 and
make adjustments to the table stop if required.
Fig 53
Fig 54-55-56
Hex key