Mains Supply Connection; Antenna For The Radio Module; Rubber Rod Antenna Used In The Control Panel; External Antenna Use - jablotron Profi JA-63K Installation Manual

Table of Contents

Advertisement

2.1

Mains supply connection

It is specified to connect the control panel by a permanent two-
wire cable. The power supply has a double isolation. The ground
wire is unattached.
 An inlet is realized by a permanent two-wire cable with a
double isolation – wire diameter 0.75 – 1.5 mm
must be connected to the independent circuit breaker (10 A
max) in the object, which has function of the switch.
 Thread the Inlet through the power supply case bushing;
connect the wires to the terminals (equipped by a fuse
T200mA / 250 V).
 Cable must be firmly fixed to the power supply board by a
sliding strap (firstly check again that the wires are firmly
secured in terminals)
3

Antenna for the radio module

If the "R" radio module is used, install its antenna (rubber rod
or an external model AN-01). The antenna must not be shielded
by any metal object in its proximity. The working range of the
wireless accessories
is about 100 meters under optimal
conditions. However, building materials can absorb or obstruct
radio signals and communication can also be effected by
interference from other radio signals. For these reasons, you
should anticipate a shorter working range for indoor installations.
3.1

Rubber rod antenna used in the control panel

There is a hole on the top of the control panel case for the
rubber antenna. The rubber antenna is supplied with the control
panel. Attach the antenna to the board using the provided screw
as shown in the diagram. The antenna must not be obstructed
by any metal object.
3.2

External antenna use

An optional external antenna, model AN-01, has a connector
which fits the connector on the radio module board. If you use
the external antenna, the
rubber antenna should not
be installed. The AN-01
antenna has a small plastic
ring on its end, used to
hang it from the wall. Its
active part (from the plastic
ring to the coil) should be
installed
vertically
and
should not be obstructed by
any large metal object. The
antenna
can
be
located
behind furniture, etc.
4
Terminals and connectors on the main
board
There is a Digital data jack for the JA-60E keypad(s) and/or for
a PC interface cable. The same connecter is also available on
the bottom right corner of the control panel housing. The digital
bus signals are also available on terminals 1234.
JA-63 „PROFI" Alarm System
2
. The inlet
1,2,3,4 digital data terminals provide an option to use standard
cable for the wiring of JA-60E keypads.
Up to four JA-60E keypads can be wired to the control panel
(connected in parallel). The total length of the keypad cables
should not exceed 100m. If using the jack connectors, the data
cable length should not exceed 10 meters. Use ordinary twisted
pair cable connected to the 1234 terminals for longer distance.
AC20V – output of the power transformer (20VAC) is connected
to this pair of terminals.
L1,L2, L3, L4 – hard wired zone inputs – detector outputs can
be wired here: see examples of wiring on page 7. For
each input it is possible to program its method of
triggering: Normally Closed loop, balanced loop (2k2)
or double balanced loop (2x 1k1) and the type of
reaction of the system (see section 9.2).
Factory default setting: all inputs are triggered as balanced
COM
common terminal to close (balance) the input
NO
is a normally open contact of the alarm output relay.
NC
is a normally closed contact of the alarm output relay.
C
is a common contact of the alarm output relay, max. load
60V / 1A. The relay is turned on during any alarm.
SIR
is an external siren output. In the normal mode it has a +U
terminal voltage. In the alarm mode it has a GND terminal
potential. Connect an ordinary external siren to +U and SIR
terminals (max. load 0,7 A). A two wires back up siren
should be connected to the GND and the SIR terminals
- 5 -
RADIO
MODULE
JA-63R
loops, reactions: L1= delay, L2= next delay, L3= instant
and L4= tamper
MGK55402

Advertisement

Table of Contents
loading

This manual is also suitable for:

Profi ja-63krProfi ja-63krg

Table of Contents