This product should be installed by professional installers. The
manufacturer assumes no liability for damages caused by incorrect
installation or improper use of this system.
1

Architecture of the control panel

The JA-63 "Profi" is a fully programmable control panel with
building block architecture. By programming, it can be split into
two separately operated sections (with a shared section). It has
a built in power supply and there is ample space for a back up
battery (12V, 1.3Ah or 2.6Ah) in the control panel case.
The JA-63K main board has 4 hard-wired inputs with
programmable triggering (NC, balanced or double balanced) and
programmable reactions.
Model JA-63KR (equipped with the "R" radio communicating
module) has 16 wireless zones. Up to two JA-60 detectors can be
enrolled into each zone (totally 32 as a maximum). In total model
63KR has 20 zones (4 wired and 16 wireless). Up to 8 wireless
controllers (remote controls or wireless keypads), a JA-60A
wireless siren and unlimited number of UC family wireless output
modules can be enrolled as well. If more zones are required,
Available models of the JA-63 system
R
control panel
module
JA-63K
no
JA-63KR
yes
JA-63KRX
yes
JA-63KRG
yes
Note: Radio module R can not be "aftermarket" installed into 63K and 63KX models. Telephone communicator X module and GSM dialer JA-60GSM can be installed
additionally to a 63K or 63KR control panels.
2

Control panel installation

The control panel should be easily accessible but not visible.
There should be a power socket available and also a
telephone line (if the system has an optional built in dialer).
Attach the control panel's rear housing to the wall (see
drilling diagram on the last page of this manual).
JA-63 „PROFI" Alarm System
X
GSM
module
module
no
no
four zone hard wired control panel
no
no
16 zones wireless (up to 32 detectors) & 4 hard wired zones
16 zones wireless (up to 32 detectors) & 4 hard wired zones & digital telephone
yes
no
communicator.
no
yes
16 zones wireless (up to 32 detectors) & 4 hard wired zones & GSM dialer.
another JA-6x control panel can be enrolled as a subsystem
(Master & Slave architecture). The master control panel receives
information from the sub control panel and it can also arm and
disarm the subsystem panel.
Telephone module "X" can communicate with a Monitoring
Station, send two voice messages, send five SMS messages
via SMS server (or dial a numeric Pager). It can also
communicate with a remote PC (using ComLink SW and a JA-
60U modem).
GSM dialer JA-60GSM sends SMS messages, calls to
predefined telephone numbers and plays audible warning,
communicates with 2 CMS, allows remote access from a phone's
keypad and can be set via web page.
Operation and programming is possible via the JA-60E
keypad. The control panel equipped with a radio module can
also be programmed and operated by a JA-60F wireless keypad
and can also be operated by RC-40, RC-22 or RC-60 remote
controls or by a JA-60D wireless keypad. Operation and
programming is also possible via a PC using PC-60A interface
and ComLink software.
the internal layout
Route all the cables to the control panel (power, input loops,
telephone line etc.) before you tighten the case to the
desired location.
Note: Only a qualified technician can provide the installation,
telephone line connection and servicing. User is not allowed to
open the cover and/or make any modification.