Exit Delay Audible Indication; Partial Arming Exit Delay Audible Indication; Entrance Delay Audible Indication; Arming And Disarming Chirps With Wired Siren - jablotron Profi JA-63K Installation Manual

Table of Contents

Advertisement

9.16

Exit delay audible indication

The exit delay can be indicated by the
keypad (for the last five seconds, the beeping is faster). The
audible indication can be disabled with this setting.
:
options
3 3 1 indication enabled
3 3 0 indication disabled
Note: wireless indoor siren UC-260 also provides this indication
Factory default setting: indication enabled
9.17

Partial arming exit delay audible indication

Partial arming with
reaction detectors. The exit delay for partial arming can be
indicated by the "beeping" of the keypad (for the last five
seconds the beeping is faster).
:
options
3 4 1 indication enabled
3 4 0 indication disabled
Factory default setting: indication disabled
Note: when this indication is disabled, the confirmation of partial arming
and disarming will
automatically be silent, regardless of the
setting.
9.18

Entrance delay audible indication

The entrance delay can be indicated by a rapid "beeping" of
the keypad. This indication can be disabled with this setting.
:
options
3 5 1 indication enabled
3 5 0 indication disabled
Note: wireless indoor siren UC-260 also provides this indication.
Setting is also valid for partial arming if system is split.
Factory default setting: indication enabled
9.19

Arming and disarming chirps with wired siren

The control panel can confirm on the SIR output arming (1
chirp), disarming (2 chirps), disarming with information in the
memory (3 chirps), and bypass or not ready component when
arming (4 chirps). This parameter sets chirps on.
:
options
3 6 1 siren chirps enabled
3 6 0 siren chirps disabled
Factory default setting: siren chirps disabled
Note: setting of chirp sounds is valid even if the siren is disabled for
alarms with parameter 320. Partial arming is always silent, if sequence
340 is selected. Chirp sounds can also be generated with the JA-60A
and UC-260 wireless siren (self-contained setting in the wireless siren).
9.20
Siren alarm in Disarm & Partial arming
The SIR output can be disabled for alarms during the Disarm
& Partial arming of the control panel (while somebody is
indoors). If the siren output is completely disabled for alarms
with parameter 320, this setting has no effect.
JA-63 „PROFI" Alarm System
sequence: 3 3 x
"beeping" of the
sequence: 3 4 x
provides an exit delay for delayed
sequence: 3 5 x
sequence: 3 6 x
sequence: 3 7 x
:
options
3 7 1 alarm in disarm & partial arming enabled
3 7 0 alarm in disarm & partial arming disabled
Factory default setting: enabled
9.21

Wireless siren alarm

The wireless siren alarm function can be disabled with this
parameter. This setting will have no influence on the outdoor
wireless siren chirp sound function if enabled in the siren. This
setting has effect only when the control panel is equipped with a
radio module:
:
options
3 8 1 siren enabled
3 8 0 siren disabled
Factory default setting: siren enabled
9.22

Indication of system problems when arming

The system regularly checks the conditions of all items
(detectors, keypads etc.). This setting ensures that the user will
be warned with 4 rapid beeps after arming, if any component of
the system is not ready for arming. Cause of the problem (for
example permanently triggered detector, lost communication
36x
etc.) will remain displayed on the keypad. If the user ignores this
warning, the system will arm after the exit delay, then the
problematic item will be bypassed for this arming period. After
disarming in such a mode, three beeps will be generated as
well.
When the indication is not selected, the problematic item will
be bypassed when arming with neither warning nor alarm.
If a permanently activated detector is deactivated during
arming (for example your main door is not closed), the bypass of
this detector will be canceled automatically and the detector will
be ready to trigger an alarm after it is activated (if you close the
door after the system is armed).
:
options
3 9 1 warning enabled
3 9 0 warning disabled
Note: if this indication is enabled, the problems will also be
indicated if there are any when leaving the programming or user
mode.
Factory default setting: warning disabled

9.23 Control panel splitting

The control panel can be split into 2 independent sections A and
B, with a shared common area C. This way the system can be
operated by two independent user groups. In fact the system in
this mode works like two independent systems. If the system is
split into sections with this setting, it is possible to address
detectors (both wireless and wired), user codes and remote
controls to the individual sections. Use the following sequences.
:
options
6 9 0 0 no splitting (partial arming available in this
6 9 0 1 splitting to sections A, B and common C
Factory default setting: no splitting
- 12 -
mode)
(C is armed automatically when both A and
B are armed)
sequence: 3 8 x
sequence: 3 9 x
sequence: 690 x
MGK55402