Equipment Specifications - VETEC P1001/6-P Manual

Panel mounting process indicator / controller
Table of Contents

Advertisement

Equipment Specifications

Bezel size
Panel Cutout
Case Depth
Weight
Case Material
Connectors
Environmental
Power
Burden
Input Signals (bipolar)
Input Resistance
Accuracy
Span tempco
Zero Tempco
24V Excitation voltage
10V Excitation voltage
Filtering
/ smoothing
A/D conversion
Display update rate
Display Range (max)
Plug-In Output Options
Analogue, Alarm, ASCII and Clock Options
Excitation Voltage Selection
Input Conditioner Board
S2
S6 S1
S8
S3
S9
S10
S5
S4
S11 S7
S12 S13
Excitation voltages
5V DC
Link S11. Open S7 and S12 and S13
10V DC
Link S11 and S7. Open S12 and S13
24V DC
Link S11 and S13. Open S7 and S12 (default)
42
48mm high by 96 mm wide (1/8 DIN)
45 mm high by 92 mm wide
125 mm including connectors
300 grammes
Black polycarbonate
Detachable Screw Terminal connectors
Storage Temperature range -20 to +70C, non condensing
Operating temperature range 0 to 50C, non condensing
Front sealed IP65. Optional cover SPC4 for IP67
100-240 VAC, 45 to 60Hz or 11-30 VDC optional
10VA maximum
0-10V, 0-5V, 1-5V, 0-10mA, 0-20mA, 4-20mA
1 Megohm for voltage, 33 Ohms for current inputs
+/-0.05% of range. Allow 30 minutes after switch-on, for thermal
stabilisation.
25 ppm/Degree Celsius
30 ppm/Degree Celsius
24VDC nominal rated at 60mA
10VDC nominal rated at 20mA
Selectable time constants of 0 to 25 seconds.
Sigma-Delta 10 conversions per second, 50/60Hz rejection
Resolution 1 in 400 000 max. over full range
10 readings per second.
-199999 to +199999, depending on available signal level.
Default Input configuration switches
9122-2470
Link S1, S2, S3, S4, S5, S11, S13.
Open S6, S7,S8, S9, S10, S12
See separate output manual for details.

Advertisement

Table of Contents
loading

Table of Contents