See the Easy/Advanced mode selection page near the beginning of this manual, and
choose advanced mode.
The Filter Jump value allows you to decide how the display will respond to a process step
change. It does this by overriding the filtering, if the input signal moves by more than a
chosen amount in one conversion. The Filter Jump default value is 10%.
This means that for noise amplitude which has a peak value of less than 10% of the input
range, filtering will be applied. Any signal movement greater than 10% of the input range will
cause the display to jump immediately to that value, without filtering. After that jump, normal
filtering will be re-applied, provided signal movement thereafter is less than 10% per con-
version.
Guidance:
For noisy systems, increase the Filter Jump value up to a maximum of 99. Choose a value
which gives a good compromise between filtering and response speed.
For reasonably clean signals, a Filter Jump value of around 10 or less will give a good
compromise between filtering and response speed to step change inputs.
!! This feature is available in Advanced Mode only !!
Set1
Digit
1
Press 3 seconds
Set1
Digit
2
Set1
Digit
3
Set1
4
Digit
Press repeatedly to accept and return to display
Set2
Output
Alarms
OK
Max/Min
Reset
Set2
Output
Alarms
OK
Max/Min
Reset
Set2
Output
Alarms
OK
Max/Min
Reset
Set2
Output
Alarms
OK
Max/Min
Reset
Filter Jump value
Lockout Switch must be OFF
Press repeatedly until you see
FiL.J.
XX
where
Jump percentage
(Default =
FiL.J.09
You can set from
DIGIT and UP or DOWN button to
increase or decrease this value.
OFF
Circuit board
ON
XX
is the Filter
)
00
to
99
. Use the
Done!