Operation Section
Selective Catalytic Reduction Warning System
Illustration 64
Reduced Performance If a fault condition exists for
the entire duration of inducement level 1, the strategy
advances to inducement level 2. The check engine
and emissions malfunction indicator lamp will
illuminate and flash slowly for a level 2 inducement-
related fault. The engine will have a 50% derate. If
the inducement is a result of a category 1 fault, then a
level 2 inducement will occur for a duration of 70
minutes for first occurrence. For repeat occurrence, a
category 1 level 2 inducement fault will occur for a
duration of 5 minutes.
If the inducement is a result of a category 2 fault, then
a level 2 inducement will occur for a duration of 10
hours. For repeat occurrence, a category 2 level 2
inducement fault will occur for a duration of 2 hours.
If the inducement is a result of a category 3 fault, then
a level 2 inducement will occur for a duration of 64
hours. For repeat occurrence, a category 3 level 2
inducement fault will occur for a duration of 5 hours.
Reduced Time
If a fault condition exists for the entire duration of
inducement level 1, the strategy advances to
inducement level 2. The check engine and emissions
malfunction indicator lamp will illuminate and flash
slowly for a level 2 inducement-related fault. If the
inducement is a result of a category 1 fault, then a
level 2 inducement will occur for a duration of 70
minutes for first occurrence. For repeat occurrence, a
category 1 level 2 inducement fault will occur for a
duration of 5 minutes.
If the inducement is a result of a category 2 fault, then
a level 2 inducement will occur for a duration of 5
hours. For repeat occurrence, a category 2 level 2
inducement fault will occur for a duration of 1 hour.
If the inducement is a result of a category 3 fault, then
a level 2 inducement will occur for a duration of 18
hours. For repeat occurrence, a category 3 level 2
inducement fault will occur for a duration of 108
minutes.
g03676215
Illustration 65
If a fault condition exists for the entire duration of
inducement level 2, the strategy advances to
inducement level 3. Inducement level 3 has the same
actions for all categories. The check engine lamp and
the emissions malfunction indicator lamp will flash at
a fast rate. A red stop lamp will illuminate solid. The
engine will have a 100% derate and be limited to
1000 rpm or low idle, whichever is greater. If the final
inducement action in the electronic service tool is set
to "Idle Down" , then engine will continue to idle at
derated condition. If set to "Shutdown" , the engine
will shut down after 5 minutes. A key cycle will allow
safe harbor mode to initiate. Safe harbor is only
allowed once. After safe harbor, the engine will be in
level 3 final inducement. If set to "Shutdown" , the
engine may be restarted, but will only run for 5
minutes at derated condition before shutting down
again. This action will continue until the issue is
resolved.
Note: Contact your Perkins distributor for repairs if a
fault occurs.
Operator Inducement Emergency
Override for Perkins Engines
Equipped with Selective Catalytic
Reduction Systems (If Equipped)
Note: The inducement emergency override will
only be allowed on a select number of engines
that may be used in emergency situations.
Contact your Perkins distributor to find out if
your engine is allowed to have this feature.
The operator Inducement emergency override can
only be enabled using Perkins supplied passwords.
The feature is disabled by default. The feature will be
enabled at the factory if allowed. If the customer
wants the feature enabled after delivery of engine,
customers need to contact a Perkins distributor.
Operator Inducement emergency override is
regulated by the Environmental Protection Agency
(EPA) and European Union (EU). Operator
inducement emergency override is only supported in
the United States. Operator inducement emergency
override is not supported in Europe or China, and not
allowed to be used in Japan. For detailed information
on activating, deactivating, or resetting override,
contact your Perkins distributor. Before you attempt
the procedures documented below, make sure that
you have read and understand all information in this
document.