3. The filter screen can be cleaned in clean water and
dried using compressed air. Refer to this
Operation and Maintenance Manual, "General
Hazard Information" for information on using
compressed air.
4. If the filter screen cannot be cleaned or the filter
screen is damaged, then the filter screen must be
replaced.
5. Install filter screen (3) into DEF tank neck adapter
(4). Press filter screen into neck adapter and
ensure that tabs (2) are located correctly. Install
cap (1).
DEF Manifold Filters (Emission
Related Component) - Replace
NOTICE
Ensure that the engine is stopped before any servic-
ing or repair is performed.
NOTICE
Care must be taken to ensure that Diesel Exhaust
Fluid (DEF) for the system are contained during per-
formance of inspection, maintenance, testing, adjust-
ing, and repair of the product. Be prepared to collect
the fluid with suitable containers before opening any
compartment or disassembling any component con-
taining fluids.
Dispose of all fluids according to local regulations
and mandates.
Ensure that the area around the DEF manifold is free
from contamination before any servicing or repair is
performed.
There are two different designs of manifold that could
be installed on your application.
Type 1 Manifold
1. Remove the manifold, refer to Disassembly and
Assembly, "Manifold (DEF Heater) - Remove and
Install" for the correct procedure.