ETHERNET/IP™: Industrial Protocol
Table 8. O2T (Output) Assembly Data Format
Byte
Description
0 – 3
Discrete Outputs
4 – 5
Last Item Sequence Number UINT
6 – 7
Last Fragment Sequence
Number
8 – 11
Output Status
12 – 13
Output Item Sequence Num-
ber
14 – 15
Output Item Total Size
16 – 465
Output Data
466 – 467 Reserved (for 32-bit align-
ment)
Table 9. Assembly Object's common services
Service code
0E
Hex
10
Hex
Connection Manager Object (06HEX)
***No supported services or attributes***
34
Data Type
DWORD
UINT
DWORD
UINT
UINT
USINT[450]
UINT
Implemented for
Class level
Instance level
Yes
Yes
Yes
Yes
Class ID
Inst ID
0x64
0x01
0x64
0x01
0x64
0x01
0x64
0x01
0x64
0x01
0x64
0x01
0x64
0x01
N/A
N/A
Service name
Get_Attribute_Single
Set_Attribute_Single
BC9180™ Base Station/Charger
Attr ID
8
9
10
11
12
13
14
N/A