Datalogic Memor 10 Quick Start Manual

Datalogic Memor 10 Quick Start Manual

Four slot battery charger
Hide thumbs Also See for Memor 10:

Advertisement

Quick Links

Memor™ 10

Four Slot Battery Charger

Quick Start Guide

Overview

The Memor 10 four slot battery charger simultaneously charges up
to four spare batteries.

Parts and Functions

Spare Battery Slots
Spare Battery Charge LEDs
822002810
(Rev. A)
Feb. 2019

Set Up

To prevent the risk of short-circuiting, connect wall power in the
following order:
1. Connect the four slot battery charger to the power supply.
2. Connect the power supply to the power cord.
3. Connect the power cord to the wall outlet. The Power ON LED
illuminates green.
2

Charge the Spare Batteries

To charge up to four spare batteries:
1. Insert the spare battery into the slot with the contacts side facing
down and then gently push it into place. Ensure the label side is
Power ON LED
facing front. The spare battery charge LED illuminates red.
2. When charging is complete, the spare battery charge LED turns
green. Lift the battery out of the slot.
3 3
1
1
The spare battery pack recharging slot is compatible with the following
Datalogic p/n: 94ACC0191 BATTERY, MEMOR 10.
The Memor 10 four slot battery charger could get warm during
charging, this is normal and does not mean a malfunction.
NOTE
Annual replacement of rechargeable battery pack avoids
possible risks or abnormalities and ensures maximum
performance.
CAUTION

LED Indicators

LED
Power ON
Solid green
Charger is powered
Spare Battery Charger
Solid red
Spare Battery is charging.
Solid green
Charging is complete.

Technical Specifications

Electrical Features
Consumption
Max 3 A
Indicators Consumption
Power on LED (green)
Spare battery charge LED (bicolored)
Environmental Features
Working Temperature
0°C to 40°C
1
Storage Temperature
-30°C to 70°C
Humidity
5-95% non-condensing
Mechanical Features
Dimensions
165.8 x 165.8 x 57.3 mm / 6.5 x 6.5 x 2.25 in
Weight
475 g / 16.75 oz
1. Charging between 15 to 40 degrees is recommended to reach the maximum
charging capability.
Status

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Memor 10 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Datalogic Memor 10

  • Page 1 1. Connect the four slot battery charger to the power supply. Memor™ 10 The Memor 10 four slot battery charger could get warm during 2. Connect the power supply to the power cord. charging, this is normal and does not mean a malfunction.
  • Page 2 This equipment Use only a Datalogic approved power supply. The use of an generates uses and can radiate radio frequency energy and, if not alternative power supply will void the product warranty, may installed and used in accordance with the instructions, may cause cause product damage and may cause heat, explode or ignite.

Table of Contents