Xml Web Service - Datalogic BC9 0 Series Software Reference Manual

Base station/charger ethernet base
Table of Contents

Advertisement

Ethernet Host Interface Operation
XML Web Service
The BC9180™ also offers the possibility of accessing data in a simplified way
for a Machine-to -Machine communication using an XML-based data repre-
sentation.All labels transmitted to Host can be accessed at the URL:
http://<Cradle_IP_Address>/FS/RAM0/xml_file.xml
or select
The XML file has the format as shown below:
The XML file will contain the data for a maximum of 50 barcode labels with
progressive counters; it is up to the Client to timely poll the BC9180™ in
order to prevent data loss. In order to provide a Client-controllable data
flow, an XML file at the maximum 50-barcode labels is only upgraded using
a rolling buffering scheme, copying forward the last 10 labels received to the
newly updated file.
The Barcode ID counters should be checked from the Client to avoid check-
ing in duplicated data .
Poll request
XML file content
Poll #a
Data
Poll #a+1
Data
...
Poll #b
Data
Poll #b+1
Data
12
XML
from the menu on the left, as shown below:
<Datalogic><CH1>Barcode_ID</
CH1><CH2>Data</CH2>
<Label_>
<counter>0000</counter>
<data>Data0 </data>
</Label>_
<Label_>
<counter>0001</counter>
<data>Data1 </data>
</Label>_
...
</Datalogic>
Data
,...,
m0
m48
Data
,...,
m0
m48
Data
,Data
,...,
m0
m48
Data
,Data
,...,
m40
m49
Notes
Starting 49 labels at time of Poll #a
No new data before Poll #a+1
50 labels in the XML file
m49
XML file updated: last 10 labels
Data
m50,
m51
rolled in the newly updated file and
labels number 50 and 51 added