Datalogic BC9 0 Series Software Reference Manual page 37

Base station/charger ethernet base
Table of Contents

Advertisement

Assembly Object (04HEX - 4 Instances)
The following tables contain the attribute, instance, data mapping, and
common services information for the Assembly Object.
Table 6. Assembly Object (04
Attribute
Instance
ID
Class
1
(Instance 0)
2
100 (0x64)
3
112 (0x70)
3
128 (0x80)
N/A
129 (0x81)
N/A
Unused (n)
N/A
1. This instance allows clients (PLCs) to monitor input data without providing output data.
2 This instance allows clients (PLCs) to monitor input data without providing output data.
3 Configuration data is not required, but it must match if supplied. Contents of the config-
Table 7. T2O (Input) Assembly Data Format
Byte
Description
0 – 3
Discrete Inputs
4 – 7
Barcode Scanner Status
8 – 9
Item Sequence Number
10 – 11
Item Total Size
12 – 13
Fragment Sequence Number UINT
14 – 15
Fragment Size
16 – 465
Fragment Data
466 – 467 Reserved (for 32-bit align-
ment)
468 – 469 Last Output Item Sequence
Number
470 – 471 Reserved (for 32-bit align-
ment)
Ethernet Software Reference Guide
HEX -
Name
Revision
Max instance
T2O (Input) Assembly (see
below)
O2T (Output) Assembly (see
below)
Input only heartbeat
Listen only heartbeat
3
Configuration
To use this connection type, an owning connection must exist from a second client and
the configuration of the connection must match exactly.
uration instance are yet to be determined.
ETHERNET/IP™ Object Model
2 Instances)
CIP Data Type Data Value
UINT
UINT
SINT[472]
SINT[468]
1
Heartbeat
2
Heartbeat
Data Type
Class ID
DWORD
0x64
DWORD
0x64
UINT
0x64
UINT
0x64
0x64
UINT
0x64
USINT[450]
0x64
UINT
N/A
UINT
0x64
UINT
N/A
Access
Rule
2
Get
129
Get
Varies
Get
Varies
Get
0
n/a
0
n/a
Inst ID Attr ID
0x01
1
0x01
2
0x01
3
0x01
4
0x01
5
0x01
6
0x01
7
N/A
N/A
0x01
15
N/A
N/A
33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bc9180

Table of Contents