MAN069 12/2018 V1.1
Table 5.7: Assignment of status line fields
Parameter width [bit]
32
24
32
8
12
24
16
8
11
11
11
11
2
2
2
16
32
32
32
16
24
32
32
4
5.11 Image Information and Status Line
Parameter Description
Preamble: 0x55AA00FF
Image Counter (see Section 5.11.1)
Real Time Counter (see Section 5.11.1)
Missed Trigger Counter (see Section 5.11.1)
Image Average Value("raw" data without taking
in account gain settings) (see Section 5.11.1)
Integration Time in units of clock cycles (see
Table 4.3)
Reserved (Burst Trigger Number)
Missed Burst Trigger Counter
Horizontal start position of ROI (OffsetX)
Horizontal end position of ROI (= OffsetX +
Width - 1)
Vertical start position of ROI (OffsetY). In
MROI-mode this parameter is the start position
of the first ROI.
Number of rows - 1 (HeightInterface - 1)
Trigger Source. 0: TriggerMode=Off; 1:
TriggerMode=On, TriggerSource=PLC_Q4; 2:
TriggerMode=On, TriggerSource=Line1; 3:
TriggerMode=On, TriggerSource=Software; 4:
TriggerMode=On, TriggerSource=ABTrigger.
Digital Gain
Digital Offset
Camera Type Code (see Table 5.8)
Camera Serial Number
Reserved
Custom value: value of register
StatusLineCustomValue that can be set by the
user
FineGain. This is fixed a point value in the
format: 4 digits integer value, 12 digits
fractional value.
Encoder Position (only available in some models,
see Appendix B).
Reserved
Reserved
Trigger Level: signal level of the trigger input
signal (only available in some models, see
Appendix B). Bit 0: PLC_Q4: Bit 1: Line1; Bit 2:
PLC_Q6 (A-Trigger); Bit 3: PLC_Q7 (B-Trigger).
This entry is only available in some models, see
Appendix B.