Specifications - Weidmuller IE-SW-PL16M Series Hardware Installation Manual

Table of Contents

Advertisement

On
CPLR/TAIL GREEN
Blinking When the Turbo Chain is down.
Off
On
10M
GREEN
Blinking Data is being transmitted at 10 Mbps.
(TP)
Off
On
100M
GREEN
Blinking Data is being transmitted at 100 Mbps.
(TP)
Off

Specifications

Technology
Standards
IEEE 802.3 for 10BaseT,
IEEE 802.3u for 100BaseT(X) and 100Base FX,
IEEE 802.3x for Flow Control,
IEEE 802.1D for Spanning Tree Protocol,
IEEE 802.1w for Rapid STP,
IEEE 802.1Q for VLAN Tagging,
IEEE 802.1p for Class of Service,
IEEE 802.1X for Authentication,
IEEE 802.3ad for Port Trunk with LACP
Protocols
IGMPv1/v2, GMRP, GVRP, SNMPv1/v2c/v3,
DHCP Server/Client, DHCP Option 66/67/82,
BootP, TFTP, SNTP, SMTP, RARP, RMON,
HTTP, HTTPS, Telnet, SSH, Syslog, IPv6, LLDP,
IEEE 1588 PTP, Modbus/TCP, SNMP Inform
MIB
MIB-II, Ethernet-like MIB, P-BRIDGE MIB,
Q-BRIDGE MIB, Bridge MIB, RSTP MIB, RMON
MIB Group 1,2,3,9
Interface
RJ45 Ports
10/100BaseT(X) auto negotiation speed, F/H duplex
mode, and auto MDI/MDI-X connection
Fiber Ports
100BaseFX (SC/ST connector)
Console Port
RS-232 (10-pin RJ45)
LED Indicators
PWR1, PWR2, FAULT, 10/100M (TP port),
MSTR/HEAD and CPLR/TAIL
Alarm Contact
Two relay outputs with current carrying capacity of
1A @ 24 VDC
When the switch coupling function is
enabled to form a back-up path, or
when it's set as the Tail of the Turbo
Chain.
When the switch disables the coupling
function.
TP port's 10 Mbps link is active.
TP port's 10 Mbps link is inactive.
TP port's 100 Mbps link is active.
TP port's 100 Mbps link is inactive.
- 13 -

Advertisement

Table of Contents
loading