Digital Input
Two inputs with the same ground, but electrically
isolated from the electronics
• For state "1": +13 to +30V
• For state "0": -30 to +3V
• Max. input current: 8 mA
Power
Input Voltage
24 VDC (12 to 45 VDC), redundant inputs
Input Current (@24V)
IE-SW-PL16M-16TX: Max. 0.44A
IE-SW-PL16M-14TX-2SC/ST: Max. 0.51A
Connection
Two removable 6-pin terminal blocks
Overload Current Protection Present
Reverse Polarity Protection Present
Mechanical
Casing
IP30 protection, metal case
Dimensions
95 135 140 mm (W H D)
Weight
1.586 kg
Installation
DIN-Rail, Wall Mounting
Environment
Operating Temperature
0 to 60°C (32 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative Humidity 5% to 95% (non-condensing)
Regulatory Approvals
Safety
UL 508, UL60950-1
CSA C22.2 No. 60950-1, EN60950-1
Hazardous Location
UL/cUL Class I, Division 2, Groups A, B, C, and
D, ATEX, Zone 2, Ex nC IIC
EMI
FCC Part 15, CISPR (EN55022) class A
EMS
EN61000-4-2 (ESD), Level 2
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 2
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
EN61000-4-11
EN61000-4-12
Shock
IEC60068-2-27
Freefall
IEC60068-2-32
Vibration
IEC60068-2-6