Specifications
Technology
Standards
Processing Type
Flow Control
Interface
M12 Ports
LED Indicators
Power
Input Voltage
Input Current
Connection
Overload Current
Protection
Reverse Polarity
Protection
Physical Characteristics
Housing
Dimensions
Weight
Installation
Environmental Limits
Operating
Temperature
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
Regulatory Approvals
EMI
EMS
Shock
Freefall
Vibration
IEEE 802.3 for 10BaseT
IEEE 802.3u for 100BaseT(X)
IEEE 802.3x for Flow Control
Store and Forward
IEEE 802.3x flow control, back pressure flow
control
10/100BaseT(X) auto negotiation speed, F/H
duplex mode, and auto MDI/MDI-X connection
Power, LNK/ACT
24 to 45 VDC
18 to 30 VAC (47 to 63 Hz)
0.12A @ 24 VDC
0.28A @ 24 VAC
M12 A-coding 5-pin male connector, single
power input
1.1 A
Present
Plastic, IP67 protection
60 x 125 x 29.6 mm (W x H x D)
250 g
Panel/Wall Mounting
Standard models: -25 to 60°C (-13 to 140°F)
Wide temp. models: -40 to 75°C (-40 to 167°F)
5 to 95% (non-condensing)
FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD), Level 3
EN61000-4-3 (RS), surpasses Level 3
EN61000-4-4 (EFT), Level 3
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 2
EN61000-4-8, EN61000-4-11
IEC 60068-2-27
IEC 60068-2-32
IEC 60068-2-6
11