Produal TRC-P Series Manual page 6

Touchscreen room controllers
Table of Contents

Advertisement

TRC-P Series User Interface
INDICATES
CURRENT MODE -
BUTTON FOR
MODE SCREEN
ACCESS
Touchscreen
Programming Times and
Targets
Web-site: www.produal.com
Enquiries: T: +358 10 219 9100 E: info@produal.fi
The figures below illustrate some of the TRC-P controller user displays. The multi-colour LCD screen
is touch sensitive, easy to adjust and illustrates clearly the plant status information.
HEATING DEMAND
Wed 12:43
Target
°C
21
.5
A
Room
20
°C
.1
TRANSITIONS BETWEEN
ROOM, HUMIDITY, CO2,
OUTSIDE (NETWORK)
CO2
Outside
Humidity
700
10
45
%
ppm
CO2 ALARM DISPLAYS
OK
CO2 AMBER
CO2 RED ALARM
ALARM
CO2
CO2
CO2
700
950
1300
ppm
ppm
ppm
The colour of the 'Energy Ring' indicates the heating/cooling demand. The 'Energy Ring' is white at
'deadzone'. The density of red/blue on the 'Energy Ring' modulates based on how far from the
Effective Heating/Cooling Setpoint the temperature is. When the difference is 2°C/3.6°F the 'Energy
Ring' is at full density
.
ENERGY RING COLOURS
-
HDz - 2°/ 3.6°F
HDz
calcSP
Deadzone
The TRC-P controller home screen has a number touch sensitive areas that allow the device settings
to be changed.
UP and DOWN arrows; to alter the current control target setpoint temperature
SCREEN DIM ICON; dims the screen backlight/ switches backlight off
SMALL ACTION CIRCLE (that contains current room and/or floor temperature, CO2, humidity
etc); allows access to FURTHER SETTINGS AND INFORMATION screen; password protected
FAN SPEED ICON; when FAN display is enabled, the fan ICON can be used to control the fan
speed
COMFORT/ECO/OFF/BOOST ICON; used to select between COMFORT/ECO/OFF/BOOST
modes. When selected, the MODE SELECTION screen is displayed and can be used to select
the mode.
The TRC-P controllers have up to five programmable time switching times that can be configured to
switch between COMFORT / ECO / OFF / BOOST modes. The times and targets can be set for
individual weekdays or the thermostat can be switched 5+2 mode where the targets are set for
WEEKDAYS or WEEKENDS.
The SCHEDULE OVERVIEW screen shows the current switching targets. By selecting the day it is
possible to adjust the switching times and targets of the device.
NOTE: Switching from the 7 DAYS mode to 5+2 DAYS mode will set all weekday/weekend to the
group settings. When returning back to 7 DAYS mode the setting are required to be re-entered for
each day.
STATUS INFORMATION
BANNER
OFF (AWAY) MODE -
BUTTON TO MODE
SELECTIO SCREEN
INTENSITY OF THE RED ON
THE ENERGY RING
CHANGES DEPENDING ON
DIFFERENCE BETWEEN
FAN STATUS AND
EFFECTIVE TARGET AND
MANUAL CONTROL
ROOM TEMPERATURES, AT
(FAN ROTATES
2°C/3.6°F FULL RED
WHEN RUNNING)
SMALL ACTION
TARGET SETPOINT
CIRCLE
ADJUSTMENT BUTTONS
PRESS DIM BUTTON TO
SWITCH BACKLIGHT OFF
WHEN ENTERING THE MODE
SCREEN THE CURRENT MODE
STATUS IS DISPLAYED.
°C
.5
BY SELECTING THE NEW MODE
THE DEVICE AUTOMATICALLY
RETURNS TO THE HOME
SCREEN (OR AFTER TIMEOUT).
+
CDz
CDz + 2° / 3.6°F
MEASURED
TEMPERATURE
Copyright © 2020 Produal Oy - All rights reserved - 07/2020
Produal Oy
COOLING DEMAND
Wed 12:43
Target
°C
21
.5
A
Humidity
45
%
MODE SCREEN