tams elektronik LD-G-24 Manual page 20

Locomotive decoder with load control for dc engines - dcc forma
Table of Contents

Advertisement

English
CV-name
Assignment
F5 – F8 to
the outputs:
X4
X5
X6
X7
Configuration
data 2
Dimming of
the outputs::
X4
X5
X6
X7
Parameter of
load control KP
2
*
Tip: You program the configuration variables CV#29, CV#39 to 42,
CV# 49, CV#55 to 58 and CV#60 to 63 by entering the sum of the
numerical values which are assigned to the desired parameters.
Page 42
CV-
Input value /
no.
(State of
delivery)
0 ... 15
(0)
39
40
41
42
49
0 ... 127
(1)
0 ... 63
(63)
50
51
52
53
54
0 ... 255
(96)
Remarks
Numerical value *
Operation with:
---
function key F5
function key F6
function key F7
function key F8
Numerical value *
Load control active
Emergency stop at
change of direction
Emergency stop at F1
Shunting gear mode at F1
Shunting gear mode at F2
Shunting gear mode at F3
Shunting gear mode at F4
= The voltage that is applied to
the output.
The value "1" corresponds to
the minimum, „63" to the
maximum voltage.
= Proportional component of
the load control.
LD-G-24
2
0
1
2
4
8
2
1
2
4
8
16
32
64

Advertisement

Table of Contents
loading

This manual is also suitable for:

22-01-08622-01-087