• Video Preview: User can check the setting via video preview pop-up window
• Exposure Control
– Mode: Determines exposure mode between automatic and Flicker-free modes.
* Automatic mode: Use the full shutter speed.
* Flicker-free mode: Due to flicker protection, a limited range of shutter is used.
– Value: Sets exposure target.
– Max. gain: Sets maximum gain threshold.
– Shutter: Determines shutter mode between automatic and fixed.
* Max. shutter: Allows you to set the threshold for slow shutter speeds used in dark
environments.
* Min. shutter: Allows you to set the threshold for fast shutter speeds used in bright
environments.
In automatic mode, Max. shutter and Min. shutter speed can be selected.
If you are monitoring a fast object such as a car, please change Max. shutter to a faster
value (ex. 1/10 -> 1/120).
In fixed mode, you can manually select the shutter speed.
NOTE: When the shutter speed is manually selected, the screen may be saturated or dark.
– IRIS: Determines Iris mode between automatic and fixed.
– IRIS F number: Select Iris F number if Iris is in fixed mode.
31