Anti-passback Function:
The master machine control OUT and the slave machine control IN.
In anti-passback (APB-In):
Only user's last record is out-record, can the door be opened. Otherwise
it will trigger the alarm signal as illegal access.
Enter: New user's first time access will pass.
In anti-passback mode not restrict of OUT.
Out anti-passback (APB-Out):
Only user's last record is in-record, the door can be opened. Otherwise it
will trigger the alarm signal as illegal access.
Out: New user's first time access will pass.
In anti-passback mode not restrict of IN.
In-Out anti-passback (APB-Out/In):
New user's first time access will pass. Only user's last record is
out-record, can the door be open when he/she want IN. Otherwise it will
trigger the alarm signal as illegal access. Only user's last record is
in-record, can the door be open when he/she want out. Otherwise it will
trigger the alarm signal as illegal access.
None anti-passback:
Slave machine can verify to open the door, and the prompt "no enrolled
data" on the master machine.
Anti-passback function is available.