7
To change a menu selection for a specific pan cavity, use the following steps:
A. Press and hold the Prince Castle Logo Button for 6 seconds. All Pan
Displays will show "PROG". All LED Timers will be red.
TRANSFER
PROG
B. Press and hold the MENU/ENTER Button. The display next to the
MENU/ENTER Button will display the menu choices. While holding the
MENU/ENTER button, press the UP or DOWN Buttons to scroll through the
menu choices.
C. Press a PAN Button to change the menu. The LED Timer will change to yel-
low and the Display will change from "PROG" to the assigned menu item.
8
To shut down the unit, turn the power On/Off switch to OFF.
TRANSFER
The unit has four shelves, each with an upper and lower heater (eight heaters total).
1
The factory pre-set for the upper heaters is 195°F.
The factory pre-set for the lower heaters is 185°F.
Each upper heater has a programmable range of 150° - 275°F.
Each lower heater has a programmable range of 150° - 225°F.
Use the control below and the following steps to set the setpoint temperatures for each heater.
UPPER SHELF LED
This LED will be lit to indicate
upper shelf is selected
PROG LED
This LED will be lit to indicate
unit is in Program Mode
LOWER SHELF & LED
This LED will be lit to indicate
lower shelf is selected
ACTUAL TEMP BUTTON & LED
Press to display actual temperature for the
selected heater. LED will be lit when actual tem-
perature is displayed.
SETPOINT BUTTON & LED
Press to display setpoint temperature of a
selected heater. LED will be lit when setpoint
temperature is displayed.
NOTE: To reset all times and temperatures to the factory settings, turn the unit off, then press and hold the UP and DOWN arrow buttons
simultaneously while turning the unit back on. A "P" will appear in the display and all times and temperatures will be reset to original factory settings.
Printed in USA 10/10 © 2010
Operation (continued)
PROG
PROG
MENU
BKFT
REG
ENTER
Setting Temperature
UPPER
U225
PROG
LOWER
ACTUAL
TEMP
SET-
POINT
4
D. Press the UP or DOWN Button to
scroll to the desired menu item.
PROG
F. Repeat steps A - E as required for other Pan Displays. Press
the Prince Castle Logo Button to exit the program mode.
NOTE: Up to six products may be programmed for each Pan
Button (1 for each menu). In addition, a pan may be set as "not
used" by assigning "----" as its product.

Cleaning

Before performing any maintenance, turn the power switch to the OFF
position and unplug the power cord from the electrical receptacle.
This unit is not watertight. Do not clean with a water jet/jet spray.
Do not immerse the unit in water.
1. Turn the unit off and unplug the power cord from the electrical
receptacle.
2. Remove the pan covers and pan racks. Wipe all parts and unit
with a damp cloth. DO NOT use a green scotch bright pad cleaner,
ice or water.
NOTE: The unit is preset to display temperature in
Fahrenheit. To display in Celsius, press and hold
the DOWN Arrow button immediately after turning
on the power switch. To switch back to Fahrenheit,
press and hold the UP Arrow button after turning
on the power switch.
Used with other buttons to scroll
through heater and temperature
PRINCE CASTLE LOGO BUTTON
Press to enter
temperature selections
Product Holding Bin
DHB2PT-33DQ Series
E. Press the MENU/ENTER button
to select the menu item.
MENU
PROG
ENTER
WARNING
CAUTION
TEMPERATURE DISPLAY
UP/DOWN ARROW BUTTONS
selections