Configuring Initial Position; Configuring Park Actions - HIKVISION DS-2DT6223-AELY User Manual

Network speed dome
Table of Contents

Advertisement

Network Speed Dome User Manual

5.4.3 Configuring Initial Position

Purpose:
The initial position is the origin of PTZ coordinates. It can be the factory default initial
position. You can also customize the initial position according to your own demand.
Customize an Initial Position:
Steps:
1. Enter the Initial Position Configuration interface:
Configuration > PTZ > Initial Position
2. Click the PTZ control buttons to find a position as the initial position of the dome;
you can also call a defined preset and set it as the initial position of the dome.
3. Click Set to save the position.
Call/delete an Initial Position:
You can click
to call the initial position. You can click
position and restore the factory default initial position.

5.4.4 Configuring Park Actions

Purpose:
This feature allows the dome to start a predefined park action (scan, preset, pattern
and etc.) automatically after a period of inactivity (park time).
www.a1securitycameras.com email: sales@a1securitycameras.com
Figure 5-31 PTZ Configuration
Available from A1 Security Cameras