Configuration Switches
The location of the switches, connectors, and LED indicators on the
MVME197DP/SP is illustrated in Figure 2-1. The MVME197DP/SP has been
factory tested and is shipped with factory switch settings that are described in
the following sections. The MVME197DP/SP operates with its required and
factory-installed Debug Monitor, MVME197Bug (197Bug), with these factory
switch setting.
Configuration Switch S1: General Information
Switch S1 is a bank of nine two-way switch segments. The following
illustration shows the factory configuration of switch S1. The bit values are
read as a one when the switch is OFF (open), and as a zero when the switch is
ON (closed). The default value for switch S1 is shown below.
1
2
3
4
O
N
MVME197/D1
Switch S1
5
6
7
8
9
CLOSED
OPEN
System Controller (SCON)
General Purpose Input 7 (GPI7)
General Purpose Input 6 (GPI6)
General Purpose Input 5 (GPI5)
General Purpose Input 4 (GPI4)
General Purpose Input 3 (GPI3)
General Purpose Input 2 (GPI2)
General Purpose Input 1 (GPI1)
General Purpose Input 0 (GPI0)
(FACTORY CONFIGURATION)