Introduction Scope and definitions This manual provides installation, operation and maintenance instructions for the Edwards ATEX Category 1, 2 and 3 Liquid Ring Vacuum Pumps (abbreviated to ‘liquid ring pump(s)’ or ‘pump(s)’ in the remainder of this manual). ATEX Category 1 model pumps are denoted by a “S” suffix on the pump designation, ATEX Category 2 model pumps are denoted by a "C"...
You must ensure that the pump is suitable for your application. If you have any doubts as to the suitability of the pump for your application, refer to the Edwards guidelines on vacuum pump and vacuum system safety (see the Associated Publications at the end of the contents list at the front of this manual).
(SG) of 0.8. For specific applications, different materials of construction and seals flush liquid with lower specific heat and specific gravity please refer to the System Manual or consult Edwards. Materials of construction Table 12 - Materials of construction: process contact parts: EHR (S/C/D) pumps...
3.10 Connect the sealing liquid and seals flush pipelines WARNING Edwards cast iron pumps are treated with a corrosion inhibitor. To avoid contamination flush with a suitable fluid. WARNING On an ATEX Category 2 pump configured for internal seals flush supplies and on an ATEX Category 3...
Check the direction of rotation of the pump as follows: 1. Edwards preferred method would be to visibly check the fan on the motor for direction of rotation. If this is not possible, temporarily remove any guard over the drive coupling or belt.
3.16.2 Use of flammable sealing/seals flush liquids: ATEX Category 1, 2 and 3 pumps Note: The acceptable pressure rise limit depends on your application. Contact Edwards for advice. If you use a flammable sealing/seals flush liquid (see Section 3.3), you must ensure that the system is sufficiently leak tight, otherwise there will be a risk of explosion during pump operation.
A750-04-880 Issue F 7. Slowly open the flow regulating valve (12) until the required sealing liquid flow rate is obtained. Refer to Tables and 7. Edwards recommend that a flow meter is installed. Cavitation and fluid hammer WARNING Do not operate the pump without sealing liquid in the pump. If you do, there may be a risk of explosion.
The pump may have overheated if it was misused, if it malfunctioned or if it was in a fire. Edwards Material Safety Data Sheets for fluorinated materials used in the pump are available on request: contact your supplier or Edwards.
The majority of these centres employ Service Engineers who have undergone comprehensive Edwards training courses. Order spare parts and accessories from your nearest Edwards company or distributor. When you order, state for each part required: Model and Item Number of your equipment ...