Setting ATW-R5220/ATW-R5220DAN

Setting the audio output level

1.
From the menu screen, turn the control dial, select [AUDIO] and
then press the control dial.
2.
Turn the control dial to set the audio output level.
• The level changes +/- 2 dB each time you turn the control dial.
• It can be set from -60 to 0 dB.
3.
Press the control dial.
• The setting is complete.

Scanning for open channels

Scan for unused channels in the current environment for use.
1.
From the menu screen, turn the control dial, select [SCAN] and
then press the control dial.
2.
Turn the control dial to select the group you want to scan. After
selecting a group, press the control dial.
• Selecting "ALL" will scan all the groups.
3.
Turn the control dial to select the preferred threshold. After
selecting the threshold, press the control dial.
• You can select [Normal], [High] or [Low] sensitivity.
High: Prioritize the number of channels.
Normal
Low: Prioritize stable operation.
• Scan starts.
Selecting [ALL]:
4.
Confirm the scan result, select the group and then press the
control dial.
5.
Select the channel selection method, and then press the control
dial.
• When selecting [Manual] and pressing the control dial, available channels
and frequencies are shown in a list. Turn the control dial, select an
available channel and then press the control dial. The setting is complete.
• When selecting [Find Best] and pressing the control dial, the optimum
channel and frequency are shown. Turn the control dial, select [Set] and
then press the control dial. The setting is complete.
Selecting the group you want to scan:
4.
Confirm the scan result by selecting [OK] and then pressing the
control dial.
• If you want to scan over again, select [Retry].
5.
Select the channel selection method, and then press the control
dial.
• When selecting [Manual] and pressing the control dial, available channels
and frequencies are shown in a list. Turn the control dial, select an
available channel and then press the control dial. The setting is complete.
• When selecting [Find Best] and pressing the control dial, the optimum
channel and frequency are shown. Turn the control dial, select [Set] and
then press the control dial. The setting is complete.

Setting transmitters via IR SYNC

This function allows you to make transmitter settings on the receiver
and then automatically configure the transmitter via IR SYNC. The
following are the available settings and setting values:
Settings
Freq
Current setting value, NoChange
Name
Current setting value, NoChange
RF Pwr
Low:2mW, Mid:10mW, High:50mW, NoChange
*1
Gain
-10 to +20dB, NoChange
Sens.
0, +10dB, NoChange
*2
Lock
Lock, Unlock, NoChange
Batt
Alkaline, Ni-MH, NoChange
HPF
OFF, ON, NoChange
*1 The selectable RF transmission output may differ depending on the country or region in
which you live.
*2 ATW-T5201 only
1.
From the menu screen, turn the control dial, select [TX SYNC]
and then press the control dial.
2.
Turn the control dial to select a setting you would like to sync to
the transmitter and then press the control dial.
3.
Turn the control dial to select the setting value and then press
the control dial.
4.
Repeat Steps 2 and 3 for each setting you would like to sync to
the transmitter.
5.
Turn the control dial, select [SYNC START] and then press the
control dial.
• Communication function is in standby. Refer to "Using IR SYNC" (p. 14)
for subsequent steps.
• This setting can also be displayed by pressing and holding (for about 2
seconds) the control dial on the receiver while on the Main screen.