Setting ATW-R5220/ATW-R5220DAN
Setting group/channel editing
Setting group/channel
Groups/Channels 01 to 10 can be edited.
• All channels are vacant in the initial state.
1.
From the menu screen, turn the control dial, select [UTILITIES]
and then press the control dial.
2.
Turn the control dial, select [Gr/Ch EDIT] and then press the
control dial.
3.
Turn the control dial, select [EDIT] and then press the control
dial.
4.
Turn the control dial, select a group and then press the control
dial.
5.
Turn the control dial, select [ON] or [OFF] and then press the
control dial.
• If you select [OFF], the group cannot be used.
6.
Turn the control dial, select a channel and then press the control
dial.
7.
Turn the control dial, select [SET] or [RESET] and then press the
control dial.
• By pressing [SET], you can set the frequency of the selected channel.
• If you press [RESET], the frequency of the selected channel becomes
blank.
8.
After setting all channels, turn the control dial, select [Sync] or
[Save] and then press the control dial.
• If you press [Save], the setting is completed.
• If you press [Sync], the screen turns to an IR SYNC standby screen. Refer
to "Using IR SYNC" (p. 14) for subsequent steps.
Syncing the Group/Channel
The Groups/Channels that have been set with [EDIT] can be set to the
transmitter in groups with IR SYNC.
1.
From the menu screen, turn the control dial, select [UTILITIES]
and then press the control dial.
2.
Turn the control dial, select [Gr/Ch EDIT] and then press the
control dial.
3.
Turn the control dial, select [Gr/Ch SYNC] and then press the
control dial.
4.
Turn the control dial to select group and then press the control
dial.
• The screen turns to an IR SYNC standby screen. Refer to "Using IR
SYNC" (p. 14) for subsequent steps.
Setting the backup frequency mode
If you set the backup frequency in advance, you can switch the
frequency of the transmitter and receiver with the transmitter. It is
convenient to set this function when you want to switch the frequency
easily.
• The default setting is [OFF].
1.
From the menu screen, turn the control dial, select [UTILITIES]
and then press the control dial.
2.
Turn the control dial, select [BACKUP FREQ] and then press the
control dial.
3.
Turn the control dial, select [ON] and then press the control dial.
4.
Turn the control dial, select [Manual] or [Gr/Ch] and then press
the control dial.
• If you select [Manual], you can set the frequency.
• If you select [Gr/Ch], you can set the group/channel.
5.
After setting each item, turn the control dial, select [Set] or
[Sync] and then press the control dial.
• If you press [Set], the setting is completed but you must still sync the
setting with the transmitter or set the backup frequency manually on the
transmitter in order to use the backup frequency.
• If you press [Sync], the screen turns to an IR SYNC standby screen. Refer
to "Using IR SYNC" (p. 14) for subsequent steps.