STEP 1
INSTALLATION OF THE SENSOR PAD UNDER THE MATTRESS
Sensor Pad(s) 1 or 2
• Position the sensor pad as shown above. Make sure the printed side faces up. Do not place any bedding between the mattress and the sensor pad.
• Secure the sensor pad cord to crib using a tie wrap. Run the cord on the floor to ensure it is out of the baby's reach.
• The sensor pad must rest on a completely flat and rigid surface. Place a 6mm (1/4") plywood to cover the full size of the crib base. Make sure
the sensor pad's cord passes underneath the mattress as shown above.
STEP 2
INSTALLATION OF THE NURSERY UNIT
STEP 3
INSTALLATION OF THE PARENTS UNIT
Charger adapter
Charger adapter
socket
socket
Battery
compartment
STEP 4
HOW YO USE YOUR ANGELCARE© MONITOR
Parents unit
pager
ON/ OFF Night
light button
Power ON/OFF
Movement
capture indicator
(Flashing)
Power ON indicator
Low battery
indicator
Microphone
Speaker
6/10/08
11:44 AM
Page 3

HOW TO OPERATE YOUR ANGELCARE

Keep at
least 38 cm
(15 inches)
apart
Sensor pad cord
socket
Adapter socket
Sensor pad
sensitivity dial
Battery
compartment
Sound volume
Power ON/OFF
UP/DOWN
®

MONITOR

POSITION OF SENSOR PAD UNDER MATTRESS
I sensor pad
Crib center
• Connect the long sensor pad cord into the nursery unit.
• Insert 4 AAA regular batteries (not included) into nursery unit (for battery
backup in case of power failure).
• Connect AC adapter to nursery unit and plug adapter into an electrical
outlet in the baby's room.
• After both units are properly installed you may adjust the sensor pad
sensitivity level (if necessary).
Note: After each start up, the monitor needs up to 1 minute before the
movement function is ready to be used.
• Insert 4 AAA NIMH rechargeable batteries (included) into parents unit.
NEVER use regular alkaline batteries.
• Connect AC adapter to parents unit charger and plug adapter into an
electrical outlet. Let charge for 15 continuous hours before using the
monitor for the first time.
• Once the parents unit is fully charged (after 15 hours) turn the unit ON and
turn the nursery unit ON. If the parents unit is turned ON and the
nursery unit is OFF, the parents unit will start beeping after 1 minutes.
After 4 seconds, the unit will shuts itself off.
• The different available options are programmable but you can use
the units right away, with the following factory settings :
- Sound, movement and tic activated
- Out of range notification OFF
- Voice activated ON
- Temperature display ON, Room temperature control OFF
- Parents unit alarm ON, vibration OFF
- Speaker volume at 3
- Voice sensitivity at 2
• To avoid feedback (whistling sound), keep both units at least 3 meters
apart (10 feet).
• You can adjust the sound volume with the arrow buttons.
• To turn the night light ON, move the right wing button UP.