When Secs Is Not Used - Omron V640-HAM11-V3 User Manual

Cidrw system, amplifier units, cidrw heads, cidrw controller, link unit
Table of Contents

Advertisement

SECTION 5
Troubleshooting

When SECS Is Not Used

Errors are indicated by the presence or absence of a response to an Amplifier Unit command, and by the
indicators.
List of Error Messages
Type
Host communi-
cations error
Communications
error between
the CIDRW Head
and ID Tag
Amplifier Unit Indicators
Name
RUN (green)
COMM (orange)
NORM (green)
ERROR (red)
CIDRW System
106
User's Manual
Response
Name
code
14
Format error
70
Communications
error
71
Verification error
72
No Tag error
7B
Outside write area
error
7E
ID system error (1)
7F
ID system error (2)
Turns ON when the Amplifier Unit is in normal operation.
Turns ON during communications with the host device or during communications with an ID Tag.
Turns ON when the communications finish with no error.
Turns ON when an error occurs during communications with the host device, or during communications
with an ID Tag.
Description
There is a mistake in the command format. (For example, the com-
mand portion is undefined, or the page or address specification is
inappropriate.)
Noise or another hindrance has occurred during communications with
an ID Tag, and communications cannot be completed normally.
Correct data cannot be written to an ID Tag.
Either there is no ID Tag in front of the CIDRW Head, or the CIDRW
Head is unable to detect the ID Tag due to environmental factors (e.g.,
noise).
The ID Tag is at a position where reading is possible but writing is not,
so writing does not complete normally.
The ID Tag is in a status where it cannot execute the command pro-
cessing.
An inapplicable ID Tag has been used.
Indications