Omron V640-HAM11-V3 User Manual page 46

Cidrw system, amplifier units, cidrw heads, cidrw controller, link unit
Table of Contents

Advertisement

SECTION 2
Installation and Connections/Wiring
• Cable Information
Recommended Models
Cable
Crimp terminals
Crimping tool
• Wiring Method
1.
Attach crimp terminals to stripped portions of the cables.
2.
Insert the wires into the correct holes in the connector, bearing
the orientation of the connector in mind.
3.
Tighten the set screws of the connector firmly to secure the
cables.
The appropriate tightening torque is around 0.5 N·m.
A standard, tapered screwdriver will not enter all the way into the
screw holes. Use a small gauge flat-blade screwdriver whose shaft
and tip have the same thickness.
Side view
0.6 mm
4.
Having fitted the connector to the cable, connect it
to an Amplifier Unit.
Orient the cable connector correctly in relation to the connector
on the Amplifier Unit, and fasten the cable connector by fully
tightening the retaining screws.
Disconnecting the connector
Fully loosen the two screws, then grip the projections on the connector and pull it straight out. If it is difficult to pull the
connector out, press down on the Amplifier Unit while pulling on the connector.
CIDRW System
44
User's Manual
RS-485 signal wire
When one wire is connected
to each terminal.
When two wires are con-
nected to each terminal.
Face view
Recommended Screwdriver
Manufacturer
OMRON
3.5 mm
Manufacturer
Tachii Electric Wire
Phoenix Contact
Model
XW4Z-00C
Set screws
Model
MVVS 2CX0.5SQ
AI0.5-8WH
AI-TWIN2×0.5-8WH
CRIMPFOX UD6
Small flat-blade screw-
driver with no taper