Omron V640-HAM11-V3 User Manual page 120

Cidrw system, amplifier units, cidrw heads, cidrw controller, link unit
Table of Contents

Advertisement

SECTION 6
Appendix
Link Unit
V700-L11
Mounting dimensions
Item
Power supply voltage
Current consumption
Ambient temperature
Ambient humidity
Degree of protection
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Ground
Case material
Weight
CIDRW System
118
User's Manual
110
41.5
26.5
41.3
18.5
20.3
100±0.2
24 VDC +10% -15%
250 mA max. (inrush current: approx. 10 A)
Operating: 0 to +40°C
Operating/Storage: 35% to 85% (with no condensation)
IP20 (IEC60529)
50 MΩ min. between power supply terminals and the frame ground terminal (500 VDC M)
Leak current not to exceed 5 mA on application of 1000 VAC (50/60 Hz for 1 minute) between
power supply terminals and the frame ground terminal
Frequency: 10 to 150 Hz; double amplitude: 0.20 mm; acceleration: 15 m/s
each in X, Y, and Z directions
Shock of 150 m/s
2
in X, Y, and Z directions, 3 times each for 18 repetitions
Ground to 100 Ω or less.
PC/ABS resin
Approx. 200 g
Two, 4.5-dia. holes
2-φ4.5
2-M4 OR φ4.2
Two M4 or 4.2-dia. holes
Specifications
Storage: -15 to +50°C (with no icing)
(Unit: mm)
60
4
for 8 minutes, 10 times
2

Advertisement