When Secs Is Used - Omron V640-HAM11-V3 User Manual

Cidrw system, amplifier units, cidrw heads, cidrw controller, link unit
Table of Contents

Advertisement

SECTION 5
Troubleshooting

When SECS Is Used

Errors are indicated by the contents of the CIDRW Controller response messages, and by the indicators.
List of Error Messages
When responses are made to messages sent by the CIDRW Controller, errors are expressed by the
contents of error messages and the nature of the SSACK response.
S
F
1
0
9
0
9
1
9
3
9
5
9
7
9
9
9
11
18
0
Controller Indicators
If an error or alarm has occurred at the CIDRW Controller, the indicators on the front of the Controller
light.
Name
OPERATING (green)
ALARMS (green)
BUSY (green)
ERROR (red)
CIDRW System
100
User's Manual
Direction
S,H←E
Abort Transaction
S,H→E
Abort Transaction
S,H←E
Unrecognized Device ID
S,H←E
Unrecognized Stream Type
S,H←E
Unrecognized Function Type
S,H←E
Illegal Data
S,H←E
Transaction Timer Timeout
S,H←E
Data Too Long
S,H←E
Abort Transaction
Lit when the operation status (status model) of the CIDRW system is operating.
Lit when the status in AlarmStatus of the CIDRW system is Alarm (1).
Lit when the status in OperationalStatus of the CIDRW system is BUSY.
When a processing error is detected (when SSACK is other than NO), this indicator is lit for 50 ms.
SECS II names
Function

Advertisement

Table of Contents
loading

Table of Contents