2.12.2 Procedure

1
Attach the power cord to the Power Supply/Cooling Modules,
2
Attach the power cord to the in-line IEC connector in this cord.
Caution
These power splitting cables are provided so that the system is operated from a SINGLE power
source thus providing a single point of disconnect.
3
Switch on each Power Supply/Cooling Module.
4
A POWER LED on the Ops Panel indicates whether AC power is present.
Caution
The power connections must always be disconnected prior to removal of the Power Supply/Cooling
module from the enclosure.

2.13 Grounding Checks

Perform these checks to ensure that a safe grounding system is provided.
• If a rack distribution system is being used.
• If a direct connection is made with the Altos S205F / S200F Storage System power cord, ensure
Warning
Some electrical circuits could be damaged if external signal cables or power control cables are
present during the grounding checks.
• Check for continuity between the earth pin of the IEC 320 connector on one of the Power
38
– Ensure power is removed from the rack.
– Connect the Altos S205F / S200F Storage System power cord to the rack distribution and the
enclosure.
that it is connected to the enclosure.
Supply/Cooling modules and any exposed metal surface of the Altos S205F / S200F Storage
System enclosure.