Acer Altos S205F User Manual page 17

Hide thumbs Also See for Altos S205F:
Table of Contents

Advertisement

1.3.1.1
AC Power Supply/Cooling Module
Two Power Supply/Cooling modules
as part of the subsystem core product.
Figure 1–7
PSU voltage operating ranges are nominally 115V or 230V AC, selected automatically.
.
Four LEDs mounted on the front panel of the Power Supply/Cooling module (see
cate the status of the PSU and the fans.
1.3.1.2
Multiple Power Supply/Cooling Modules
The Altos S205F / S200F Storage System must always be operated with two Power Supply/Cooling
modules fitted. The two Power Supply/Cooling modules operate together so that if one fails the
other maintains the power supply and cooling while you replace the faulty unit.
Module replacement should only take a few minutes to perform but must be completed within 10
minutes from removal of the failed module.
(Figure
AC Power Supply/Cooling Module
1–7) are supplied mounted in the rear of the enclosure
5
Introduction
Figure
1–7) indi-

Advertisement