Acer S205F / S200F User's Manual
Table 2–1
Module
Blank I/O Module
Ops Panel
Table 2–2
Module
Drive Bays
Power Supply/Cooling
Modules
JBOD I/O Module
Blank I/O Module
Ops Panel
Caution
Dummy Carriers and Blank Modules MUST be fitted to ALL unused bays, there will be inadequate
drive cooling if any are left open.
20
Altos S205F Storage System Configuration
Location
If only one RAID I/O moudle is installed a blank module must be fitted
in the unused bay. No bays should be left completely empty.
(integral part of chassis assembly) Installed in rear Bay 2
Altos S200F Storage System Configuration
Location
ALL
drive bays must be fitted with either a drive carrier module or a
dummy carrier, no bays should be left completely empty. All drive
carrier modules provide SES Management Services.
Two Power Supply/Cooling modules must be fitted. Full power and
cooling redundancy is provided while a faulty module is replaced. Install
the Power Supply/Cooling modules in rear Bays 1 & 5.
Note: Rear bays are numbered from 1 to 5 commencing from the right
hand side)
Two JBOD I/O modules should be Installed in rear bays 3 and 4. If only
one module is fitted. Install in rear Bay 4
If only one JBOD I/O moudle is installed a blank module must be fitted
in the unused bay. No bays should be left completely empty.
(integral part of chassis assembly) Installed in rear Bay 2