Chapter 2

Getting Started

2.1 Introduction

In this chapter, you are shown how to install your Altos S205F / S200F Storage System enclosure and
plug-in modules into an industry standard 19 inch rack cabinet.
Caution
When connecting up the Altos S205F / S200F Storage System , use only the power cords supplied or
cords which match the specification quoted in section 1.5.5.

2.2 Planning Your Installation

Before you begin installation you should become familiar with the configuration requirements of
your Altos S205F / S200F Storage System. The correct positions of each of the optional plug-in
modules are shown in
I/O module configurations and installation.
Table 2–1
Module
Drive Bays
Power Supply/Cooling
Modules
RAID I/O Module
Figure 2–1
and
Figure 2–2
Altos S205F Storage System Configuration
Location
ALL
drive bays must be fitted with either a drive carrier module or a
dummy carrier, no bays should be left completely empty. All drive
carrier modules provide SES Management Services.
Two Power Supply/Cooling modules must be fitted. Full power and
cooling redundancy is provided while a faulty module is replaced. Install
the Power Supply/Cooling modules in rear Bays 1 & 5.
Note: Rear bays are numbered from 1 to 5 commencing from the right
hand side)
Install in rear Bays 3 and 4.
(If only 1 controller is fitted it must be installed in bay 4).
. Please refer to sections
Getting Started
2.5
-
2.7
for details of
19