Chapter 2 Preparations
1.9

PCI Card

This server provides a riser card. The riser card can connect either of a Low Profile PCI card or a RAID
controller.If an optional N8116-31 PCI riser card is used, a RAID Controller can be connected to a connector for
LAN riser card.

1.9.1 Precautions

Read the following precautions when installing or removing a PCI card.
Do not touch the terminals of the riser cards and the leads of electronic components with your bare hand.
Fingerprints and dust left on them cause the server to malfunction due to a connection failure or damage to
the leads.
Available type of PCI card depends on riser card. Make sure the card type before connecting it to riser card.
The server does not provide LED connector to indicate disk access.
The PCI devices of the same type (including onboard PCI device) may be detected in different order from
that described above, depending on OS or RAID Configuration Utility. Check the slot location of PCI device
by PCI bus number, device number and function number shown in the table below.
Onboard LAN1
Onboard LAN2
PCI slot (Low Profile)
LAN riser card slot
If an additional LAN card is installed, it is hard to push the catch of the connector with your finger that is
connected to the LAN card. Disconnect the connector pushing the catch with a standard screwdriver. At this
time, be very careful for the screwdriver not to damage the LAN connector or other card.
If a bootable device such as a PCI card or USB device is added, the boot order may change.
In BIOS Setup Utility, select Hard Drive BBS Priorities from the Boot menu, and check priority for the boot
device.
Boot → Hard Drive BBS Priorities → Check the display
If the boot device is an HDD under an optional RAID Controller, the display is (Bus xx Dev 00) PCI RAID
Adapter. (xx changes depending on the PCI slot where a RAID board is installed.)
If a hard disk drive that contain OS is not connected with RAID Controller, LAN card (network boot), or Fibre
Channel controller, set the option ROM for that slot to Disabled. Refer to Chapter 2 (1. System BIOS) in
"Maintenance Guide" for how to specify it.
Important You must avoid static electricity to work with the procedure below. For details, refer
to Chapter 2 (1.2 Anti-static Measures).
PCI device
Bus number
Express5800/E120e-M User's Guide
1. Installing Internal Optional Devices
Device number
08h
0
08h
0
20h
0
10h
0
Function number
0
1
X
X
59