<Cover sensor device setting screen>
<Needle bar cover sensor ON/OFF setting screen>
1. The cover sensor device does not function only by setting the ON or OFF of the corresponding cov-
er. Place the cover sensor function in ON on the cover-sensor function ON/OFF setting screen.
2. The cover sensor for the hook (left) is not used for the LU-2828V. Place the cover sensor for hook (left)
in OFF.
5) In the case the cover sensor function is
6) Place the selected over sensor in ON if it is
7) Press
– 162 –
placed in ON, it is necessary to set the ON/
OFF status of the respective cover sensors.
When the cover sensor of which is to be set
is selected, the cover-sensor ON/OFF setting
screen for the selected cover is displayed.
used, or in OFF if not.
❼ to confirm the setting.