4
1.3 OPERATING ELEMENTS AND CONNECTIONS
Side 1 - 2 - 3
1. CONTROL PANEL with display and 4 button
used to access the control panel functions
and manage them.
2. MICROPHONE to control the show by the
external audio signal.
3. SAFETY EYE to attach safety cable
4. POWER IN mains plug for connection to a
socket (100-240V 50/60Hz) via the supplied
mains cable. The support for the mains fuse
is located near the mains plug. Only replace a
blown fuse by one of the same type (T1A 250V).
TRUSSPOD3T
1
Mic
2
MEMU UP DOWN ENTER
3
4
6
7
Power IN
Power OUT
DMX IN
DMX OUT
5. POWER OUT: connect to supply power to the
next unit.
6. GND POINT grounding the fixture to the earth
7. DMX IN (3-pole XLR):
1 = ground, 2 = DMX -, 3 = DMX +
8. DMX OUT (3-pole XLR):
1= ground, 2 = DMX -, 3 = DMX +
5
8
Fig.1