Specifications Of Sc-915/916; Function Setting Procedure Of Sc-915/916; How To Change Over To The Function Setting Mode - JUKI IP-100A Engineer's Manual

Computer-controlled, direct-drive, high-speed, 1-needle, lockstitch, zigzag stitching machine
Table of Contents

Advertisement

7. SPECIFICATIONS OF SC-915/916

1) SC-915
(For use in Japan)
Supply voltage Single phase 100V 3-phase 200V
Frequency
Rated currency
Operating
Temperature : 0 to 40˚C
environment
Humidity : 90% or less
Destination
Item
Supply voltage
Single phase
100V/110V/120V
Frequency
Rated currency
8.0A/7.5A/7.0A
Operating
Temperature : 0 to 40˚C
environment
Humidity : 90% or less
2) SC-916
(For use in Japan)
Supply voltage Single phase 100V 3-phase 200V
Frequency
Electric power
Temperature : 0 to 40˚C
Operating
Humidity : 90% or less
environment
Destination
Item
Supply voltage
Single phase
100V/110V/120V
Frequency
Electric power
Operating
Temperature : 0 to 40˚C
environment
Humidity : 90% or less

8. FUNCTION SETTING PROCEDURE OF SC-915/916

(1) How to change over to the function setting mode

(Caution) 1. Do not perform switch operations other than those described in the following explanations.
2. Be sure to re-turn the power switch ON after one second or more has passed.
3. If the power is turned ON immediately after turning it OFF, the sewing machine may not
work normally. In this case, turn ON the power again.
WARNING :
To avoid possible personal injuries caused by movement other than that you desired, do not operate
the switches in the procedure other than those required, as described below, to specify the functions.
There are two kinds of function settings, Level 1 and Level 2.
Level 1 : Change of setting can be performed without turning OFF the power switch.
Level 2 : It is necessary to turn OFF the power switch after change of setting.
For the details, refer to "9. FUNCTION SETTING LIST".
[Setting procedure of Level 2]
1) Turn ON the power. When the needle bar is not in its UP position, turn the handwheel to bring the needle bar
to its UP position.
50 Hz / 60 Hz
8A
3A
For JUS
3-phase 200V/
220V/240V
50 Hz / 60 Hz
3.0A/2.7A/2.3A
50 Hz / 60 Hz
600VA
For JUS
3-phase 200V/
220V/240V
50 Hz / 60 Hz
600VA
Destination
Item
Supply voltage
200V/220V/240V
Frequency
Rated currency
Operating
environment
Destination
Item
Supply voltage
Frequency
Rated currency
Operating
environment
Destination
Item
Supply voltage
200V/220V/240V
Frequency
Electric power
Operating
environment
Destination
Item
Supply voltage
Frequency
Electric power
Operating
environment
107
For general export
Single phase
3-phase 200V/
220V/240V
50 Hz / 60 Hz
4.6A/4.3A/4.0A
3.0A/2.7A/2.3A
Temperature : 0 to 40˚C
Humidity : 90% or less
For CE
Single phase 220V/230V/240V
50 Hz / 60 Hz
4.3A/4.2A/4.0A
Temperature : 0 to 40˚C
Humidity : 90% or less
For general export
Single phase
3-phase 200V/
220V/240V
50 Hz / 60 Hz
600VA
Temperature : 0 to 40˚C
Humidity : 90% or less
For CE
Single phase 220V/230V/240V
50 Hz / 60 Hz
600VA
Temperature : 0 to 40˚C
Humidity : 90% or less
2) P r e s s s w i t c h 1 f o r
a p p r o x i m a t e l y t h r e e
seconds.
1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lz-2290a seriesIp-100dSc-915Sc-916

Table of Contents