• Make the user manual available to all installers and operators and save the manual
for future reference.
• If you have questions about the safe operation of the impression E350, please contact
an authorized GLP distributor (see list of distributors at www.glp.de).
• Use the product only as directed in this user manual. Observe all markings in this user
manual and on the product.
• Refer any service operation not described in this manual and refer all repairs to a
technician authorized by GLP.
• The light source in this product must not be changed by the end user.
• Read and follow the user documentation for all additional equipment.
Electrical safety
• Do not allow the product to come into contact with water or moisture.
• Use only a source of AC mains power that complies with local building and electrical
codes and has both overload and ground fault (earth fault) protection.
• Ensure that the product is electrically connected to ground (earth).
• Disconnect the product from AC mains power before carrying out any installation or
maintenance work and when the product is not in use.
• Disconnect the product from power immediately if the power plug or any seal, cover,
cable, or other component is damaged, defective, deformed, wet or showing signs
of overheating. Do not reapply power until the product has been repaired and made
safe by a technician authorized by GLP.
• Before using the product, check that all power distribution equipment and cables are
in perfect condition and rated for the electrical requirements of all connected
devices.
• Use only a Neutrik powerCON TRUE1 cable connector for AC power input at the
product's power connector.
• Use minimum 14 AWG or 1.5 mm
16 A rated and temperature-rated to suit the application. In the USA and Canada the
cables must be UL-listed, type SJT or equivalent. In the EU the cables must be type
H05VV-F or equivalent.
• The supplied power input cable is rated as follows:
- US power cable: 16 A, 14 AWG, UL listed, E304117, SJT, 4.9 ft.
- EU power cable: 16 A, 1.5mm², H05VV-F, 1.5 m
• If a fuse blows, replace it with one of the original type and rating only. If new fuses
blow, disconnect the product from power and send it to a technician authorized by
GLP for repair.
GLP® impression E350 User Manual
power input and relay cables that are minimum
2