If you need to install a Neutrik powerCON TRUE1 connector on a power cable, follow
the instructions given in the Support area of the Neutrik website at www.neutrik.com.
Respect the color coding used in the supplied power cable and in your local mains
power wiring system. US and EU systems use the color coding shown below:
US system
EU system
Main fuse
See Figure 12. The main fuse sits in a holder in the
base.
If the fixture appears to be completely shut down
even though power is applied, the main fuse may
have blown. Disconnect the fixture from power
before replacing the fuse. You can open the
fuseholder with a flat-headed screwdriver. Replace
only with a fuse of the same type and rating.
If the fuse blows repeatedly, disconnect the fixture
from power and contact GLP for service and
repair.
Connecting to a DMX control data link
The impression E350 provides 5-pin and 3-pin XLR IN and THRU sockets for connection to
a USITT DMX512 data link.
Connectors use standard DMX pinout:
• Pin 1 = Ground
• Pin 2 = Negative / data cold
• Pin 3 = Positive / data hot.
• Pins 4 and 5 are not used.
If you would like any advice with planning and installing a DMX link, your GLP supplier
will be happy to provide assistance.
22
Live or L
Neutral or N
Black
White
Brown
Blue
Ground / Earth or
Green
Yellow/green
Figure 12. Main fuse
GLP® impression E350
User Manual Rev. A