Warnings!
The cabinet, chassis or guide rails may cause serious
scratches, please be careful while handling.
When installing new servers into the cabinet in use, please
be aware of electric shock.
When installing 4U or bigger servers, at least 4 people are needed or use the auxiliary equipment.
During the installation process, please do not block the vents on the server, especially the
vents on the front and rear of the server.
●Please remove the protective film from the server surface before using.
Please leave a minimum of 15cm clearance on the front and rear sides of the server for proper
ventilation.
Please install air baffles in place prior to device installation, to make sure that the server can
get enough air flow, and to avoid air turbulence in the server room.
Servers are high-power electrical appliances, and they should be installed into dedicated
cabinets with vents or professional water-cooled cabinets, to prevent system failures
causedby overheating.
If it needs to install more than one device, please load them from the bottom to the top, and
load the heaviest items first.
Please note the cabinet's load-bearing capacity, power supply capacity and heat dissipation
capacity, be sure not to install devices beyond the cabinet's threshold capacity.
For the convenience of using the front and rear ports of the server and cabling, leave a
minimumclearanceof 70mm between the front end of the server and the inner side of the
cabinet'sfront door, and 150mm between the rear end of the server andthe inner side of the
cabinet's rear door.
If the device is more than 15kg, at least 2 people are needed.
15kg
If the device is more than 30kg, at least 3 people are needed.
30kg
If the device is more than 50kg, at least 4 people are needed.
50kg
Please keep this document for future reference.
PN
4U Server
Installation Guide
V1.0

Advertisement

loading
Need help?

Need help?

Do you have a question about the NF5488M5 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Inspur NF5488M5

  • Page 1 Warnings! The cabinet, chassis or guide rails may cause serious scratches, please be careful while handling. When installing new servers into the cabinet in use, please be aware of electric shock. ● When installing 4U or bigger servers, at least 4 people are needed or use the auxiliary equipment. ●...
  • Page 2 4U Server Installation Guide V1.0 Removing Server and Rail Kit Installing the front side of the rail Installing Rail Kit and Server into the cabinet:Position the front bracket on the cabinet. Keep the front and rear brackets in the same Removing the server This rail is suitable for 9.2*9.2mm, 9.5*9.5mm square-hole cabinets and Ø7.1mm round-hole 2U space.①Open the latch.