Wiring/Installation
 When Using Top/Bottom + Intermediate Brackets
1.
Loosen the hexagon socket head cap screws (M3 x 18) of Intermediate Bracket (3) and change the
direction of Intermediate Bracket (2) according to its mounting direction. (Figure 6 and 7)
Next, loosen the hexagon socket head cap screws (M3 x 12) of Intermediate Bracket (1) so that it can
be mounted to the case of the sensor.
For side mounting, the direction of Intermediate Bracket (2) that is inserted into Inermediate Bracket
(3) can be left-right in reverse.
Backside mounting
Hexagon socket head
cap screw (M3 x 18)
Side mounting
Hexagon socket head
cap screw (M3 x 12)
Hexagon socket head
cap screw (M3 x 18)
2.
Mount the Intermediate Bracket to the case, and then lightly tighten the hexagon socket head cap
screws (M3 x 12) of Intermediate Bracket (1). (Figure 8)
Intermediate Bracket (1)
Tighten lightly
F3SJ-B
50
User's Manual
Hexagon socket head
cap screw (M3 x 12)
Loosen
Intermediate Bracket (1)
Loosen
Intermediate Bracket (3)
Figure 6
Intermediate Bracket (1)
Intermediate Bracket (2)
Loosen
Intermediate Bracket (3)
Backside mounting
Optical surface
Intermediate
Bracket (2)
Sensor is secured by
Intermediate Brackets.
Intermediate Bracket (2)
Intermediate
Bracket (2)
Figure 7
Optical surface
Intermediate
Bracket (3)
Intermediate Bracket (2)
Figure 8
Change the direction of
Intermediate Bracket (2) and insert it
into Intermediate Bracket (3).
Intermediate Bracket (1)
Loosen
Intermediate Bracket (3)
Side mounting
Intermediate Bracket (1)
Tighten lightly
Intermediate
Bracket (3)
Sensor is secured by
Intermediate Brackets.