Omron F3SJ-B0185P25-01TS User Manual page 109

Safety light curtain
Table of Contents

Advertisement

Control Unit
Appearance
Control Unit
Appearance
Control Unit
Appearance
Control Unit
Appearance
Model
Output
G9SA-301
Relay with three N.O.
and one N.C.
contacts
Model
Output
G9SB-301-B
Auto reset, three
N.O. and one N.C.
contacts
G9SB-301-D
Manual reset, three
N.O. and one N.C.
contacts
G9SB-200-B
Auto reset, two N.O.
contacts
G9SB-200-D
Manual reset, two
N.O. contacts
Model
Output
G9SX-AD322-T15
Solid state outputs
(instantaneous
outputs x 3, off-delay
outputs x 2)
Model
Output
G9SP-N10S
Safety outputs: Solid
state outputs x 4
Test outputs: 4
Standard outputs:
Solid state outputs x
4
G9SP-N10D
Safety outputs: Solid
state outputs x 16
Test outputs: 6
G9SP-N20S
Safety outputs: Solid
state outputs x 8
Test outputs: 6
Appendix
Remarks
• An F39-JDA single-ended cable is
required.
• A PNP type of F3SJ-B can be connected.
• A type of five N.O. and one N.C. contacts
is also available.
Remarks
• An F39-JDA single-ended connector
cable is required.
• A PNP type of F3SJ-B can be connected.
• Thickness of a type of three N.O. and one
N.C. contacts is 22.5 mm.
• Thickness of a type of two N.O. contacts
is 17.5 mm.
Remarks
• An F39-JDA single-ended connector
cable is required.
• A PNP type of F3SJ-B can be connected.
• Off-delay within 15 seconds can be set in
16 steps.
• The off-delay output can be used as
instantaneous output by setting it to 0
second.
• Can be configured for partial control and
total control.
• Can be extended to connect a relay unit.
Remarks
• An F39-JDA single-ended connector
cable is required.
• A PNP type of F3SJ-B can be connected.
User's Manual
E
F3SJ-B
95

Advertisement

Table of Contents
loading

Table of Contents