In-Line/Local - TEC EO1-32004 Owner's Manual

Label/receipt printer
Table of Contents

Advertisement

9.
PROGRAMMING PROCEDURES
9.14

IN-LINE/LOCAL

Menu Page: 2
Item No.:
3
When the H-9000 is used as a satellite in an in-line system, the "ID #" and "Transmission delay time"
can be set by the following procedure.
<MENU>
Page 2
The transmission
delay time can be
set when in-line
system is selected
for TMCC.
(Refer to Table 5)
NOTES: 1. The TMCC baud rate is fixed to 4800 BPS.
2. After setting the ID #, turn the power switch OFF and ON again.
3. This setting is not available in case that the Initial set #13-6 is set to 1 (LAN: allowed).
g Table 5: Transmission Delay Time Table
TR-Time (ms)
1
20 - 39
2
40 - 59
3
60 - 79
4
80 - 99
5
100 - 119
3
Select mode
l
l
TR-Time (ms)
6
120 - 139
7
140 - 159
8
160 - 179
9
180 - 199
The default is 3.
Set ID numbers
TMCC
(Range: 0-255)
OFF-line
<MENU>
PROG.
ENTER
ESC.
<MENU>
9- 23
ENTER
Page 2
Main
9.14 IN-LINE/LOCAL

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tec h-9000nH-9000n-usTec eo1-32004beTec h-9000

Table of Contents