Battery Charging

The snow blower is equipped with two 12 V batteries connected in series (24 V
total). Recharge each battery separately if you use a 12 V battery charger.
The battery is rated at 35 Ah (Ampere-hours) for USA model / 30 Ah for
Canadian model. Charging current should equal 10% of the battery's Ampere-
hour rating. A battery charger should be used that can be adjusted to deliver 3.5
amps for USA model / 3.0 amps for Canadian model.
For the method of the battery charging, follow the charger instruction manual.
1. Connect the battery charger following the manufacturer's instructions.
2. Charge the battery 5—10 hours.
3. Clean the outside of the battery and the battery tray compartment with a
solution of baking soda and water.
SERVICING YOUR SNOW BLOWER
The battery will expel explosive hydrogen
gas when overcharged.
A spark or flame can cause the battery to
explode with enough force to kill or
seriously hurt you.
Always use a regulated charger that
provides the correct charging current to
prevent overcharging.
Wear protective clothing and a face shield,
or have a skilled mechanic perform the
battery maintenance.