Canon LBP1760P Service Manual page 51

Table of Contents

Advertisement

c. Heater broken wire detection
The CPU detects heater broken wire in the following cases and assesses warm-up error or abnor-
mally low temperature.
1) The thermistor, in the low-temperature detection mode, does not rise +10°C from the initial
temperature within about 2.5 seconds after the heater is turned ON.
2) The thermistor, in the low-temperature detection mode, does not rise +20°C from the initial
temperature within about 2.5 seconds after rising +10°C from the initial temperature since
the heater is turned ON.
3) The thermistor, in the high temperature detection mode, does not exceed about 160°C with-
in about 20 seconds after rising +20°C from the initial temperature since the heater is turned
ON.
4) When the thermistor is in the high temperature detection mode and the initial temperature
is 85°C or below, the temperature does not exceed about 160°C within about 20 seconds
after the heater is turned ON.
5) When the thermistor is in the high temperature detection mode and the initial temperature
is 85°C or more, it does not exceed about 160°C (about 140°C in case of 1200DPI) within
about 6 seconds after the heater is turned ON.
6) During print temperature control, the condition of below about 150°C (about 130°C in case
of 1200DPI) lasts for more than about 1 second continuously.
d. Abnormally high temperature detection
The CPU assesses abnormally high temperature detection if the thermistor in the high temper-
ature detection mode detects over about 220°C
regardless of the heater operation condition.
for more than about 100ms continuously,
CHAPTER 2
2 - 13