7. Removal of the duplexing unit sole-
noid
1) Remove the left cover.
2) Follow the steps 1) and 2) in the duplex-
ing unit driver PCB removal procedures
to remove the upper feed guide and the
lower feed guide.
3) Disconnect the connector, then disen-
gage the cable from the cable guide.
4) Remove the E-ring and then the lever.
Connector
Cable
Cable guide
E-ring
Lever
Figure 3-10-13
5) Remove the 2 screws, then take out the
duplexing unit solenoid.
Screws
Duplexing unit solenoid
Figure 3-10-14
8. Removal of the duplex feed motor
1) Remove the right cover, left cover and
top cover.
2) Follow the steps 1) and 2) in the duplex-
ing unit driver PCB removal procedures
to remove the upper feed guide and the
lower feed guide.
3) Open the rear cover, remove the screw,
then the connector cover.
Screw
Connector cover
Figure 3-10-15
4) Open the rear cover, and then discon-
nect the 3 connectors.
Connectors
Figure 3-10-16