At the end of the operation, in the event of a flashing LED light (2 minutes) and an
9
*
intermittent buzzer (30 seconds), this is to inform the operator that the wireless signal
to indicate the blades have fully traveled has not been received.
The display will show the following flashing screen (Ref. to section 7.6 for further
10
details).
STEP 2 – Position the unit
Position the blades of the cutting head perpendicularly around the cable that has been identi-
fied for the cut. The cutting head must then be manually positioned around the cable.
TC085-KV-RC3: release latch (4) to open the blades.
insert the cable, close the head and fully secure the latch (4) (Ref. to Fig. 8).
Ensure that the head is fully secured: partial closure may damage the head.
TC096-KV-RC3: insert the cable between the blades (Ref. to Fig. 9).
TC120-KV-RC3: extract the locking pin (9) to open the blades.
Insert the cable, close the head and fully secure the locking pin (9) (Ref. to Fig. 10).
Ensure that the head is fully secured: partial closure may damage the head.
Make sure the blades are positioned exactly on the desired cutting point.
Once the blades of the cutting head are around the cable to be cut, stabilise the head by its
support (8) to prevent any movement during the cutting operation;
If required connect one end of the grounding cable to the cutting head and the other end to
the relevant grounding attachment (Ref. to section 4.2).
Connect the flexible hose to the cutting head (Ref. to Fig. 6),
Fully unwind the flexible hose.
Position the pump as far as possible from the cutting point and connect it to the flexible
insulated hose.
Do not place the pump on dirty surfaces or in the presence of water.
Place the pump such that the flexible hose can be laid "zigzag" on the ground.
This precaution is to compensate for shortening of the hose while the pump is operating.
If for any reason the minimum 10m radius no entry zone cannot be established, other
precautionary measures must be taken (e.g. embankments
or protection walls) to protect the operator from a possible
disturbance arc due to a short circuit.
Insert the battery.
Wake up the pump by pressing forward the control button (12)
(display ON).
The operator should now move away from the pump.
17AW125
60°
max 90°
RESET
SW:S1J76202
.........
01
OK
SAVE 60%
100
LED
ON
NTC
FAULT
12
18