Download Print this page

Cembre B68RC3-85 Operation And Maintenance Manual page 16

Portable battery hydraulic cutting units radio controlled

Advertisement

4.1) Preparation
Only remove the cutting head from its case at the work place.
TC085-KV-RC3: mount the support handle (3) on the head
by screwing it onto the threaded pin (14); when finished using
the unit, remove the handle before storing the head in its case.
4.2) Grounding the cutting head
In Germany (see BGI 845) no earth conductor must
be connected to the cutting head. In some European
countries, the earth connection is used to favour the
intervention of single phase short circuit protective devices.
For countries other than Germany contact the electricity supply utility.
Should it be needed, the earthing device, comprising a 5m long cable and an earth rod, may be
ordered from Cembre (Part. no EK 500P).
Whatever the case, the earthing device must be approved by Cembre.
To ground the cutting head, proceed as follows:
Unscrew knob (6) from the grounding socket (16) of the head.
Connect the terminal of the grounding wire to the socket using the knob (6), fasten the knob
tightly.
Fully unwind the grounding wire and connect the other end to the grounding system using
the clamp.
1/2" -13 UNC
Thread
1/2" -13 UNC
Thread
grounding wire
16
6
14
3
6
16

Advertisement